Panel

GMP 101
GMP 102
GMP 201
GMP 202
GMP 203
GMP 204
GMP 510

Controller Type

Smart
DSE 701
DSE 710
DSE 5110
DSE 5210
DSE 5310
DSE 5510

ATS FUNCTION

Remote start

AMF Function

-

-

DSE 720

DSE 5120

DSE 5220

DSE 5320

DSE 5520

ENGINE PROTECTIONS

Low oil pressure

High coolant temperature

Battery/DC alternator fail

Over-speed

Under-speed

-

Fail to start

Fail to stop

-

Emergency Stop

-

-

Low coolant  level*1

Low fuel  level*2

-

-

-

-

Sensor failure

-

-

High/Low battery voltage

-

-

-

-

Two stage protection

-

-

-

-

ECM fault Codes (SAE J1939)*3

-

-

-

-

-

Low coolant temperature

-

-

-

-

-

-

ALTERNATOR PROTECTIONS

Over frequency

Under frequency

-

Over/Under voltage

-

-

Loading voltage

-

Over-current

-

-

-

Reverse power

-

-

-

-

-

-

Loss of excitation

-

-

-

-

-

-

Earth fault

-

-

-

-

-

-

High Negative Sequence current

-

-

-

-

-

-

ENGINE MEASUREMENTS

Engine oil pressure

Engine coolant temp.

Engine speed

Battery voltage

Fuel level*2

-

-

-

-

Intake manifold pressure (SAE J1939)*3

-

-

-

-

-

Intake manifold temperature (SAE J1939) *3

-

-

-

-

-

Fuel temperature (SAE J1939)*3

-

-

-

-

-

Barometric pressure(SAE J1939) *3

-

-

-

-

-

ALTERNATOR  MEASUREMENTS

Frequency (Hz)

Voltage (V)

Current (A)

Power Measurements

-

-

-

-

Enhanced Power Measure.

-

-

-

-

-

-

Energy meters

-

-

-

-

-

-

CONFIGURATION

Panel buttons and leds

-

Service Tool

-

-

-

-

-

-

Laptop

-

-

COMMUNICATION

PC (RS232)

-

-

-

-

SCADA

-

-

GSM

-

-

-

-

CAN bus-SAE J1939*3

-

-

-

-

-

MOD bus RS485 (optional)

-

-

-

-

OTHER FEATURES

Event log memory

-

-

-

-

Weekly exerciser

-

-

-

-

High voltage

-

-

-

-

Fuel pump control*2

-

-

-

-

Parallel operation

-

-

-

-

-

-

Spare digital  inputs

♦ 1

-

♦ 2 P

♦ 5 P

♦ 6 P

♦ 6 P

♦ 8 P

Spare digital outputs

-

-

♦ 4 P

♦ 3 P

♦ 5 P

♦ 3 P

♦ 5 P

Expansion units for outputs, inputs & leds (Optional) *4

-

-

-

-

 
"♦" Available as Standard
"P" Programmable parameters
"_"Not Available.
*1: Low coolant level is standard for Gensets above 200 kVA.
For Lower ratings,it is an option
*2: This feature is only available when the fuel level sensor is connected.
The fuel level sensor is an extra option.
*3: The SAE J1939 is a CAN Bus communication that is only available with
Perkins electronic engines.